• https://externalassets.unilogcorp.com/ASSETS/DOCUMENTS/ITEMS/EN/RAE_Systems_by_Honeywell_T02_0003_000_User_Manual.pdf

RAE Systems by Honeywell T02-0203-000 AutoRAE 2 Automatic Test and Calibration System, For Use With QRAE 3 Pumped Monitors, Configuration: PC Based Via ProRAE Studio II Software

  • ITEM CODE: RAESY-T020203000

  • Min. Order Qty: 1
  • Qty. Interval: 1

loading

RAE Systems by Honeywell T02-0203-000

DESCRIPTION

The AutoRAE 2 automatic test and calibration system for RAE systems portable monitors makes instrument testing and calibration compliance as easy as pressing a button. Simply cradle the monitor and the system takes care of calibration, testing, and battery recharging. The AutoRAE 2 system is flexible and modular, and can be configured to efficiently meet your calibration and records management requirements. An AutoRAE 2 system can be as simple as a single cradle deployed in stand-alone mode to calibrate one instrument at a time or as powerful as a networked, controller-based system supporting 10 instrument cradles and 5 distinct calibration gases or gas mixtures.


RAE Systems by Honeywell Automatic Test and Calibration System, Series: AutoRAE 2, 400 mLpm, For Use With: QRAE 3 Pumped Monitors, 110 to 240 VAC Input/12 VDC Output, PC Based Via ProRAE Studio II Software, -60 to 60 in WC, Red/Green/Yellow LED Light Indicator, 12.6 in Length, 6-1/2 in Width, 4.65 in D

APPLICATIONS

Environmental, Fire Service, Industrial, National Security and Oil and Gas

  • Automatic testing, calibration and charging system
  • Deployable as a stand-alone cradle or a controller-based system with up to 10 cradles
  • Controller with a large, color LCD display
  • Networking capability
  • Up to 5 calibration gas cylinders can be connected at the same time
  • Automatic instrument FW update option
  • Instruments data logging file recorded automatically on controller SD card
  • Bench-top or wall-mounted use
  • Instruments supported: ToxiRAE Pro, QRAE3, MicroRAE, MultiRAE
  • Single cradle for all QRAE 3 and ToxiRAE Pro family instruments
  • The high-resolution color display on the controller provides a rich, intuitive user experience
  • Supports a wide variety of gases, including exotics
  • 2 seven-segment LEDs display
  • 2 buttons
  • 90 dB at 12 in audible alarm
  • 3 inlets (1 dedicated fresh air inlet and 2 configurable calibration gas inlets) and 1 exhaust port
  • Connectors with 200-series barbs and 1/8 in ID tubing gas port
  • Demand flow regulator - 0 to 1000 psig/70 bar
  • USB type B port for direct connection to PC
  • 5 to 95% relative humidity (non-condensing)

back to top